    Guys, whats the name of the device used to pin point where a break in the umbilical has occured?
    P.S. The answer is not eyes

    #33499
    Deepanshu
    Participant

    (TDR)Time domain reflectometer -copper wires

    (OTDR)Optical time domain reflectometer – Fiber

    Magnograph for mechanical strength of umbilical strands

    #33500
    Paul Mitchell
    Participant

    Cheers!

    #33501
    Glevum
    Participant

    You can alos us a low voltage DC power supply and a meter if there is a short to another core at the break. You can use the potential divider method.

    If you apply a voltage to one core from one end to the other you can measure the voltage on the shorted core to the powered core. The break will be a the point indicated by the voltage ratio of the measured voltage to the voltage applied.

    #33502
    Dao Tuan Anh
    Participant

    This one would help: Bicotest Lexxi T810 Cable Fault Locator

    http://www.cuthbertsonlaird.co.uk/Detail.asp?ProdID=469

    Tuan Anh